Trane chiller tonnage by model number of Technology
![Trane Model RTAC (150) Ton Chiller · – Type- Air cool.](/img/300x450/1437304437713.webp)
Trane Water chiller model number Can someone please let me know how to work out the capacity of a Trane chiller from the model number? The one I have got …View & download of more than 8942 Trane PDF user manuals, service manuals, operating guides. Air Conditioner, Heat Pump user manuals, operating guides & specifications. Sign In Upload. Manuals; ... Show all Trane Chiller manuals . Chiller Control System. Models . Document Type . RLC-SVU02F-E4 . Owner's Manual ... Model 012 GEH . Operation …Make sure you’ve entered your serial number correctly. If you’re trying to register a new ductless system, enter the serial number followed by a “-” and then the model number (example: 5001234T-MSZ-GE25VA-E1). The model number of a Trane unit often contains information about the unit’s tonnage. Method 1: Look for the Tonnage in the Model Number. Trane model …I am looking to confirm what the actual tonnage of each chiller is, age, along with oil charge capacity (how many gallons or pints) I have also attached a PDF picture of the chiller placards. The following are the model and serial numbers off the two chillers: Chiller One: Model - CVHE-028F-AG-2KB2533CE1C13CEZ00000000061C00 Serial # L85E28540of Model CVGF, 50 Hz and 60 Hz chillers with the AdaptiView Controls platform. See Figures 2 and 3 for an illustration of a CVGF Centrifugal Chiller with the Adap-tiView Unit Control Panel. These chillers are equipped with microcomputer-based control systems. A careful review of this information along with the submittal©2020 Trane CG-PRC017Q-EN Introduction Design and manufacturing excellence makes Trane a leader in the air-cooled chiller market place. This tradition of using ex cellence to meet market demands is illustrated with the Trane 20 to 130 ton air-cooled scroll chiller. This next-generation chiller is an exciting step forward in energy-The Series L™ CenTraVac™ chiller (model CVHL) is a direct result of the Trane commitment to provide the right technology for the right application at the right time. Because industrial processes and data center applications have unique cooling requirements, the RTAA-130 Installation, Operation And Maintenance Manual. 40 pages. PRGD series Installation, Operation And Maintenance Manual. 170 pages. R Series Installation, …Trane Water chiller model number Can someone please let me know how to work out the capacity of a Trane chiller from the model number? The one I have got …Trane air-cooled Series R® chillers are designed for year round operation over a range of ambient temperatures. The Model RTAC chiller will operate as standard in ambient temperatures of 25 to 115°F (-4 to 46°C). With the low ambient option, these units will operate down to 0°F (-18°C). If anTrane YHC060F Pdf User Manuals. View online or download Trane YHC060F Owner's Manual. Sign In Upload. ... Model Number Descriptions - 3 to 5 Tons (T/Y - 17 Plus) 10. Model Number Notes. 11. General Information. 12. Unit Inspection. 12. Storage. 12. ... Air Conditioner Heat Pump Chiller Air Handlers Thermostat. More Trane ManualsAug 27, 2023 · Follow the steps below to determine the tonnage of your Trane AC unit: Look for the model number of your Trane AC. Look for the seventh and eighth digits and treat them as a 2-digit number. Divide this number by 12. The result is the capacity of your Trane air conditioner in tons. Unfortunately, the way model numbers are written might be ... Trane 4TEE3F39A1000A Pdf User Manuals. View online or download Trane 4TEE3F39A1000A Installer's Manual. Sign In Upload. Manuals; Brands; Trane Manuals; ... Convertible Variable Speed – Air Handlers 3.5 - 5 Ton. Brand: Trane | Category: Air Handlers | Size: 2.22 MB Table of Contents. Table of Contents. 1 ... Air Conditioner Heat …Trane air-cooled Series R® chillers are designed for year round operation over a range of ambient temperatures. The Model RTAC chiller will operate as standard in ambient temperatures of 25 to 115°F (-4 to 46°C). With the low ambient option, these units will operate down to 0°F (-18°C). If an1.6 Trane Packaged Rooftop Air Conditioners. 1.7 Trane Split System Condensing Units and Remote Chillers. 1.8 York Air-Cooled Scroll Chillers Guide. 1.9 York Equipment Nomenclature Chart. 1.10 Aquasnap Model Number Nomenclature Chart. 1.11 Aquasnap Model Number Nomenclature / Chiller Model Number Chart. 1.12 Carrier …impact. Your Trane sales engineer can help you select the right CenTraVac chiller based on your specific performance criteria. EarthWise Systems6 savings as compared to Conventional Systems7 operating at 100% energy consumption 6EarthWise Systems Waterside: 12°F ∆T across evaporator, 15°F ∆T across condenser, high-efficiency chiller.Some of the major advantages of the Model RTAA 70-125 vs its larger predecessor are: • Higher energy efficiency. • Lower sound levels. • Smaller physical footprint. The Series R ™ Model RTAA 70-125 is an industrial grade design built for both the industrial and commercial markets. It is ideal for schools, hospitals, retailers, office ...Re: Trane Water chiller model number. check your model in cats and there are models that model CGAFC, CGAFW, CGAFD WHAT IF YOU CAN SAY THAT FOR DIGIT IS THE NUMBER OF 40TR. 23-06-2010, 11:32 AM #9. Hoaster Guest. A chilled-water applied system uses chilled water to transport heat energy between the airside, chillers and the outdoors.View AC unit costs and the cost for a new furnace and find out the price of a new unit before you contact a Trane technician. ... More energy-efficient models save you energy and monthly costs. 45%. 39%. 36%. 45%. 39%. 36%. ... Phone Number. Next.The prices listed here reflect the national average costs of installing of a new HVAC system or unit. The prices are estimates, for convenience only and subject to change. Trane makes no representation as to the accuracy of the pricing of any product displayed, and your dealer may quote you a different price that is not shown here. ©2021 Trane AC-SVX002E-EN Introduction Read this manual thoroughly before operating or servicing this unit. Warnings, Cautions, and Notices ... Model Number Descriptions . . . . . . . . . . . . . . . . 7 ... ACXA = Air-Cooled Scroll Heat Pump Chiller Digit 5, 6, 7 — Nominal Tonnage 140 = 140 Tons 160 = 160 Tons 180 = 180 Tons 200 = 200 Tons 215 = 215 …Trane Chiller Water Cooled 320 Tons Model CVHE320. Trane Chiller Water Cooled 320 Tons Model CVHE320. $5.2B Global Marketplace for Asset Recovery & Surplus Inventory. Categories; Manufacturers; Regions; Post a Listing. Browse + Post a Listing. Close All Listis ...powered by BrainBox AI®. Use the power of AI to optimize your system performance. Trane Autonomous Control works 2/47 to optimize your building to to drive efficiency and carbon reduction without sacrificing comfort. Learn about Trane Autonomous Control.Model Number Descriptions - 3 to 10 Tons (T/Y) Digit 1 — Unit Type T = DX Cooling Y = DX Cooling, Gas Heat Digit 2 — Efficiency S = Standard Efficiency H = High Efficiency Digit 3 — Airflow C = Convertible Digit 4,5,6 — Nominal Gross Cooling Capacity (MBh) 036 = 3 Ton 048 = 4 Ton 060 = 5 Ton 072 = 6 Ton 074 = 6 Ton, Dual CompressorThe chiller nameplate is located on the front of the control panel. Use the unit model number nomenclature to identify specific features and options of an Multistack chiller module. Multistack Water-Cooled Modular Chillers Multistack invented the modular chiller. Multistack modular chillers are available in a wide range of capacities, and with two120–4000+ Tons (450–14000+ kW), 60 and 50 Hz March 2020CTV-PRC007R-EN Product Catalog ©2020 CTV-PRC007R-ENTrane Introduction World’sMostEfficientLowestEmissionsChillerToday the HVAC market is concerned with issues such as indoor air quality (IAQ) and CFCs that demand a change in HVAC products. In addition, renovation has overtaken new construction in the fan coil market—demanding a design that caters to renovation issues. Trane is concerned with these issues, too.Our locations carry Trane OEM parts built to the original equipment specifications and are proven to support Trane equipment. Shop at Trane Supply today! ... Trane branded R-22 and R-410A, 6.2 ton - 30 ton, light commercial & commercial scroll compressors are built to the same tolerances and standards of the compressors in the original equipment. ...Serial Number #1E-123456 (used in 1970’s) 1 = 1971 E = May. Serial Number #P16-12ABCD (used in 1983) P = 1999 16 = week. Serial Number #03161-ABCDE (used in 2002-2009) 03 = 2003 16 = week 1 = day. Serial Number #1604-12345A (used in 2010-present) 16 = 2016 04 = week This Trane serial number style is still used in any …Trane air-cooled Series R® chillers are designed for year round operation over a range of ambient temperatures. The Model RTAC chiller will operate as standard in ambient temperatures of 25 to 115°F (-4 to 46°C). With the low ambient option, these units will operate down to 0°F (-18°C). If anTrane CenTraVac® chillers feature a time-tested and proven low-pressure design utilizing environmentally friendly refrigerants R-514A and R-1233zd. They provide the safety of low pressure with continued product enhancements in a leak-tight design. Available in a wide range of cooling capacities, CenTraVac chillers provide from 120 to 2,000 ...Capacity Range: 20 to 130 tons (50 and 60 Hz) Refrigerant: R-410A Energy Efficiency Rating (EER): IPLV: 13.7-16.6 (high-efficiency); 14.5-16.9 (extra-high-efficiency) Sintesis® Air-Cooled Chillers At a Glance: Capacity Range: 115 to 520 tons Refrigerant: R-134a or R-513A Compressor Design: Helical rotary screwComfortLink® II communicating technology connects all of the products in your HVAC system. This allows your products to communicate and automatically adjust to keep your home comfortable. Your HVAC system will also get advanced diagnostics and system performance updates, so it runs at optimal levels throughout its lifetime.Trane air-cooled Series R® chillers are designed for year round operation over a range of ambient temperatures. The Model RTAC chiller will operate as standard in ambient …Trane air-cooled Series R® chillers are designed for year round operation over a range of ambient temperatures. The Model RTAC chiller will operate as standard in ambient …Feb 24, 2022 · ©2022 Trane RLC-PRC020K-EN Introduction To meet a wide range of applications in the me dium-tonnage, water-cooled market, Trane is proud to recommend the model RTHD helical-rotary liquid chiller.This chiller provides application versatility, ease of installation, control precision, reliability, energy efficiency, and operational Enjoy the convenience of decoding multiple units simultaneously with our batch lookup tool. We are currently working on a model number decoder where we can bring you vital unit specifications based on model number. This information portal is put together by a few enthusiasts with the goal to remove friction for HVAC technicians and professionals.Model Number Descriptions Unit Model Number Digits 1, 2 - Unit Model RT = Rotary chiller Digit 3 - Unit Type A= Air-cooled Digit 4 - Development Sequence C = Development sequence Digits 5, 6 and 7 - Nominal Capacity 120 = 120 Nominal tons 130 = 130 Nominal tons 140 = 140 Nominal tons 155 = 155 Nominal tons 170 = 170 Nominal tons Aug 2, 2021 · After the last two digits of the first digits, Trane model numbers often start with a series of letters. To give you an idea of the scale of things, consider this: 18 = 1.5 tonnes, 24 = 2 tonnes, 30 = 2.5 tonnes, 36 = 3 tonnes, 42 = 3.5 tonnes, 48 = 4 tonnes, 60 = 5 tonnes. Water-Cooled Helical Rotary Chiller. At a glance. Capacity Range: 80 to 450 tons, 60 Hz; 60 to 450 tons, 50 Hz. Refrigerant: R-134a or R-513A. Best Full-load Efficiency: 0.6200 kW/ton (at AHRI conditions) Best Part-load Efficiency: 0.4800 kW/ton. Compressor Type: Helical Rotary. Medium Pressure. Re: Trane Water chiller model number. check your model in cats and there are models that model CGAFC, CGAFW, CGAFD WHAT IF YOU CAN SAY THAT FOR DIGIT IS THE NUMBER OF 40TR. 23-06-2010, 11:32 AM #9. Hoaster Guest. A chilled-water applied system uses chilled water to transport heat energy between the airside, chillers and the outdoors.20 To 130 Tons Cgam Trane Air Cooled Chiller. ₹ 65,000/ Unit Get Latest Price. Tonnage: 20 to 130 tons. Brand: Trane. Model Name/Number: CGAM. Refrigerant Used: R410A. Temperature Range: -20 to 125 Deg F. Frequency Hz: 50 and 60 Hz.RLC-PRC049J-EN 9 ApplicationConsiderations Certainapplicationconstraintsshouldbeconsideredwhensizing,selecting,andinstallingTrane …This Used Trane 120 Ton Air Cooled Chiller (Qty 2) has been inspected and is located in our facility in Bridgeport, Tx. We Buy and We Sell New and Used Chillers, Cooling Towers and Equipment. ... Model Number: CGAM120; Year: 2015; 120 Tons Nominal Cooling; 208-230V/3Ph/60Hz; Refrigerant: R-410a; Microchannel Condenser Coils; Scroll …Trane Commercial Parts. Founded in 1885 as a family plumbing business, Trane, Inc. is a leading manufacturer of HVAC systems. It manufacturers commercial units like: Water-Cooled, Air-Cooled & Modular Chillers. P Series, NV Series & N-Gen Ductless Systems. Rooftop, Split & Self-Contained Packaged Units. FIG. 1 – MODEL YK MAXETM CHILLER EVAPORATOR SYSTEM OPERATION DESCRIPTION (SEE FIG. 2) The YORK Model YK MaxETM Chiller is commonly applied to large air conditioning systems, but may be used on other applications. The chiller consists of an open motor mounted to a compressor (with integral speed increasing gears), …Aug 1, 2012 · For example, 2 chillers, with one having the serial number "L09H1234" and the other "L09H1235". A lot of information is contained in the Model Number. The nominal size is given in the 5th, 6th, and 7th characters. Those are then multiplied by 10 to get the nominal size, in tons. For example, CVHE095, would be a 950 Nominal Ton chiller. You can determine the size in tons of your American Standard HVAC system by examining the model number on the data sticker at the side of the a/c condenser (outdoor unit). Look for the 7th and 8th digit of the model number. It will be a number divisible by 6 or 12, and represents the nominal BTU of the system in thousands. A ton …This Trane (American Standard) style began use in 2002. It consists of at least 3 or 4 digits at the beginning of the serial number. From 2002 to 2009: Year of manufacture can be determined by using the 1 st position (digit) of the serial number. The 2 nd & 3 rd positions (digits) of the serial number represent week. Starting in 2010:Trane Performance Climate Changer air handlers are designed to optimize your HVAC system with high energy efficiency, indoor air quality, and low maintenance. Learn more about the features and benefits of this versatile and reliable air handler model in …The chiller is designed to deliver proven Trane performa nce based on the redesign of a European model that has been a market leader, plus all the benefits of new heat transfer and fan desi gns, as well as, low-speed, direct-drive scroll compressors. Important Design Features and New Features IntelliPak 2 offers unit design flexibility Điều hòa chiller trane. Helical Rotary Liquid Chi©2023 Trane CG-PRC017T-EN Introduction Des