ECM-1™ Troubleshooting VOLTS A/C MOTOR LEADS MOTOR W1 W2 W3 B O R Y1 Y2 BK T G VOLTS A/C 1. Is there 24 V.A.C. between terminals “R” and “B” at air handlers, or furnace? YES: #2. NO: Check 24 V.A.C. fuse and power to air handler. Repair as required. Possible component faults which could cause fuse to blow.Find the most common problems that can cause a Trane Furnace not to work - and the parts & instructions to fix them. Free repair advice! En español. 1-800-269-2609 24/7. Your Account. Your Account. ... Care Guides & Literature Parts Trane Miscellaneous Parts Trane Motor Parts Trane Paint Parts Trane Panel Parts.*See your participating independent Trane Dealer for complete program eligibility, dates, details and restrictions. Instant rebate up to $650. All sales must be to homeowners in the United States. Void where prohibited. Valid on Qualifying Equipment only. Offer valid 09/15/2023 - 11/15/2023. ¹Subject to credit approval.This item: OEM Upgraded Trane American Standard 1/2 ECM BLOWER MOTOR MODULE D341313P01 . $480.95 $ 480. 95. Get it Nov 1 - 6. In Stock. Ships from and sold by North America HVAC. + Duralight Furnace Hot Surface Ignitor Direct Replacement For Trane American Standard IGN00034 and IGN00054.Product Dimensions ‏ : ‎ 6 x 6 x 6 inches; 1 Pounds. Item model number ‏ : ‎ CECOMINOD058642. Date First Available ‏ : ‎ October 18, 2013. Manufacturer ‏ : ‎ Trane. ASIN ‏ : ‎ B00FZUB2N4. Best Sellers Rank: #671,996 in Tools & Home Improvement ( See Top 100 in Tools & Home Improvement) #440 in Furnace Replacement Circuit Boards.Jul 26, 2018 · Trane Variable Speed Diagnosis. Have a trane system with a variable speed blower. Checked ecm module with the ecm tester and its good. Ohmed the motor itself all three pegs read 11 so the motor is good. When starting the fan it will twitch forward then backward about an inch at a time then stop for a few seconds and try again. TROUBLESHOOTING. ECM Motor Background ECM MOTOR. The ECM, or Electronically Commutated Motor, is a "smart". motor. Meaning it can be programmed to react to specific. conditions. The ECM is electronically adjustable with an analog signal sent. to the speed controller, or in some cases automatically adjusts.ECM Motor Troubleshooting. Welcome to Enertech University, online training by Enertech. This video is designed to help technicians troubleshoot an ECM …3-Phase Power Troubleshooting: In the event that a fan motor has an electrical issue or is grounded and fuses blow, an alternative method to replacing fuses repeatedly is to temporarily wire in a circuit breaker in place of the fuse block. Fuse size are 30 amps, so a circuit breaker rated smaller is recommended.maintenance and troubleshooting data. 3 Simplified Three-Wire Connection Allows for easy installation and is less invasive to the structure of your home. 4 Variable-Speed Blower Motor With Comfort-R ™ Allows for quieter system startups and shutdowns, and more even heating throughout your home. Comfort-R technology regulatesTR200 VFDs are orderable factory-mounted and commissioned on IntelliPak, Voyager III, and M-Series and T-Series Climate Changers. Trane TR200 VFDs are also integral to CenTraVac Remote Mounted Air-Cooled AFDs. The Trane TR200 features and flexibility also make it ideal for stand-alone control of exhaust fans, pumps, and cooling towers. Our ...Trane ECM 2.3 motor module 16 pin connector signaling. Have seen posts that the 16 pin connector has signaling for delay tap, cool tap select, Adjust tap and heat tap that can be either full wave 24 VAC, 12VDC and also + or - half wave rectified by simple diode from the 24VAC transformer.Jan 6, 2020 · This one covers the repair of the ECM motor end bell when the surge control thermister fails. The thermistor will sometimes overheat, causing an open circui... Page 103: Troubleshooting (Ecm) ON. Notes: • The new Trane BLDC system is a closed loop system that has equipment protections and envelope enforcements. Do not assume that the motor has failed without first consulting the ECM engine status/ diagnostics screen. Page 104: General Information (Ecm)Resolution: Jumper may be missing or needs to be removed from motor plug to reverse motor rotation. See attached diagram. Jumper is on lines 22-23 on your unit schematic. Jumper is between P5 and P11 on motor plug for single phase units. On three phase units with 1.5 or 3 HP motors the jumper is located on the 12 pin connector at the drive.Most Of The Furnaces Have The Ge Ecm Motor. If you have an ecm motor tester, skip this test and follow the procedures for your ecm tool. Web ecm motor troubleshooting enertech university 88k views 7 years ago trouble shooting a trane variable speed motor rob’s garage 68k views 7 years ago. Web 0:00 / 5:40 fast easy ecm fan motor ...Troubleshooting Steps | Variable Speed ECM Blower Motors. Check the main control board in the air handler. Wiring connections, including the thermostat wire coming from the thermostat. Always perform these checks with the power turned off. Check for loose connections, corrosion, and burned spots on the board.ECM is a high efficiency, programmable motor technology. Motors require less maintenance, are more reliable and have a longer service life. They can be ...The ECM variable-speed fan motors are used in condensers that have a modulating compressor. They are also used in condensers that have two compressors or two-stage compressors. The ECM motor adds to the efficiency of the system by modulating the condenser fan motor. The speed matches the compressor that runs based on demand. In this HVAC Furnace Video, I go over the Top 8 Problems with the Inducer Motor (Induced Draft Motor) on a Natural Gas or Propane Heater. I show how to check...GE Genteq ECM 2.3 1/2 HP Blower Motor 5SME39HL0252 D341314P02 D341314P04 MOTO9232 quantity. Add to cart. Add to cart. We ship same day if ordered by 3PM ET M-F. Free ground shipping; Estimated delivery date available during checkout by UPS. All ECM motors run on 110V-120V, 208V, 220V-240V;If the jumper does not fix the fan running backwards take a look at how the motor is being controlled. For example: if 24v is constantly being supplied to the run command (I.e. CSTI board), disconnect the 24v run command, cycle power to the unit, wait a few seconds and give the 24v (G) signal to run (CSTI = TB3, 3.4 or 5) or 0-10VDC input (TB4 ...Does motor start? (The motor will only run at 50% in this mode) If yes, check the thermostat or thermostat wiring between the air handler and thermostat location. If no, …Furnace or AC blower motor prices are $100 to $500 for the part alone. Blower motor repair costs $150 to $700, depending on the problem and warranty status. Furnaces, central AC systems, and heat pumps use the same blower motor type. The blower motois part of the air handler. A new air handler costs $1,500 to $3,400.PSC vs ECM motor. PSC Motor. ECM Motor. It stands for Permanent Split Capacitor. It stands for an Electronically Commutated Motor. PSC motors only have a single speed level. ECM motors have a variable speed property and can change the speed at any time. It always runs to its full speed and capacity.Terms of Use | Privacy Policy All trademarks referenced are the trademarks of their respective owners. © 2023 Trane.All Rights Reserved.19 Mei 2021 ... In this HVAC training article, we will be discussing how to adjust the fan speeds on an indoor ECM variable speed blower motor and an ECM ...trane.com We are committed to using environmentally conscious print practices. ©2018 Ingersoll Rand Company 72-1312-07 11/18 Trane dealers are as hard to stop as a Trane itself. Independent Trane dealers are as personally invested in your comfort as you are, and take great pride in creating your perfect indoor environment.Jan 5, 2016 · How to program a ecm motor module. I have a Trane air handler in the attic Model # TWE040E13FA1 The blower stopped working December 2013, Bought the blower module very expensive. $374 dollars this December it stopped working again, The fan rocks back & forth but does not spin, I read in one of the forums that the programming could be corrupted ... How to program a ecm motor module. I have a Trane air handler in the attic Model # TWE040E13FA1 The blower stopped working December 2013, Bought the blower module very expensive. $374 dollars this December it stopped working again, The fan rocks back & forth but does not spin, I read in one of the forums that the …In this HVAC Training Video, I Show 10 Common Blower Fan Motor Problems and I Explain Why The Blower Motor is Not Running, Not Working during Fan Mode, Air C...ECM Motor Troubleshooting. Welcome to Enertech University, online training by Enertech. This video is designed to help technicians troubleshoot an ECM …PSC Motor Nameplate PSC Motor Nameplate Typical Capacitor Rescue EcoTech Example Scenario: • OEM Motor has 10 0 Amp Rescue EcoTech Selection Example Amps Hp MFD* To Use 115V Replacements 2.5-5.5 1/4-1/3 5-7.5 5520ET OEM Motor has 10.0 Amp draw with 40 MFD capacitor (115V) and labeled as 3/4 HP • Since that 40MFD capacitor is 55 …Troubleshooting a Genteq X13 Blower Fan Motor Step By Step in a Heater or Air Handler!This is How to Test or Troubleshoot a Genteq ECM X13 Blower Fan Motor. ...- I've confirmed the ECM is getting 120V - On the ECM 16 pin connector I've jumped the #1 & #3 pins with common, and the #12 & #15 pins to hot, and the motor still …In this HVAC Furnace Video, I go over the Top 8 Problems with the Inducer Motor (Induced Draft Motor) on a Natural Gas or Propane Heater. I show how to check...Does motor start? (The motor will only run at 50% in this mode) If yes, check the thermostat or thermostat wiring between the air handler and thermostat location. If no, continue to step #4 Figure 1 If you have a variable speed motor tester (PUB #34-3403-01) use this test kit, follow the printed instruction for the test kit’s correct use.With two unique heating stages and an AFUE (Annual Fuel Utilization Efficiency) rating of up to 80%, Trane’s XV80 Gas Furnace is a system you can count on. The variable-speed motor allows this system to operate at different speeds, depending on what you need, to create the optimal indoor temperature for you.In this HVACR Video, we go over the Troubleshooting of the ECM 3.0 Variable Speed Blower Motor and Testing with and without the TecMate Pro. I show you where...A blower motor resistor is the electric component that controls your vehicle HVAC system’s fan speed. While pretty reliable, they won’t last forever. This particular OE one (left) retired after close to 20 years on the clock. ... That quick little bit of troubleshooting told us that the heater core was good and that the blower motor had ...*See your participating independent Trane Dealer for complete program eligibility, dates, details and restrictions. Instant rebate up to $650. All sales must be to homeowners in the United States. Void where prohibited. Valid on Qualifying Equipment only. Offer valid 09/15/2023 - 11/15/2023. ¹Subject to credit approval. trane.com We are committed to using environmentally conscious print practices. ©2018 Ingersoll Rand Company 72-1312-07 11/18 Trane dealers are as hard to stop as a Trane itself. Independent Trane dealers are as personally invested in your comfort as you are, and take great pride in creating your perfect indoor environment.Terms of Use | Privacy Policy All trademarks referenced are the trademarks of their respective owners. © 2023 Trane.All Rights Reserved.To check for these signs of a dirty or defective furnace sensor, follow these steps: Switch off the furnace. Close the gas supply valve. Open the furnace and locate the flame sensor. Assess the flame sensor for soot and corroding or cracked/damaged sensor porcelain insulation.There’s no need to spend hundreds of dollars on a professional for a task like this. Step 1: Turn off the gas and power to your furnace. Step 2: Remove the panel cover of the furnace. Step 3: Find the furnace draft inducer. Again, this can usually be found in the upper-left corner.ECM Motors Troubleshooting Tips WARNING • VelociTach motor control board configuration must Hazardous Voltage! perfectly match the factory-supplied ECM. Failure to disconnect power before servicing could – Refer to “Adjustments, ” page 92 for configuration of result in death or serious injury. Disconnect all electric the motor control ...Step 1: Remove the start command from the unit. If a ZN or UC controller is being used, turn the zone sensor to "off" If a CSTI board is being used, turn off thermostat or 3rd party …6 Jun 2021 ... ... ECM blower motor is supposed to work. The blower fan on my home HVAC ... I also received a custom motor tester tool a long time ago from Trane.There are many possible reasons your AC is not cooling the house. In an air conditioning system, many parts work together to help your air conditioner function properly, and if something goes wrong with one, it could impact the entire system.If your AC is not cooling the house, some common AC problems homeowners face might be that the filters are …Trane ecm wont start. Power to board. Blower light on board comes on. red diagnostic blinks (normal no call for heat). CFM light blinks slightly when blower wheel is turned by hand. then blinks when I stop the when I stop the wheel. Otherwise no indication from CFM light.120 volts through all the ac lines through the board and all the way to ...In this HVAC Training Video, I show How to Quickly Diagnose an ECM Constant Torque Blower Fan Motor. Its actually a pretty easy process but many techs get ov... Need help repairing ECM board. I have a Gentec ECM fan motor from a Trane condensing unit that was not working. The motor tested fine, 10.8 ohms in all windings and no shorts between windings and frame. So, the ECM control board seem to be the culprit. I removed the top cover that houses the ECM control board, hoping to find the thermistor that ...Verify 24 vac is present on motor terminal 15 (wire 117V Black) using motor terminal 1 (wire 101PR Blue) as a common. This is the run signal from RTRM J1-11. *Note, not all versions have 24vac input to motor. DC Voltage Checks. Verify PWM signal is present on motor terminal 10 (wire W99 Yellow) using motor terminal 3 (wire W100 Blue) as a common.impact to the environment. Trane advocates the responsible handling of all refrigerants-including industry replacements for CFCs and HCFCs such as saturated or unsaturated HFCs and HCFCs. Important Responsible Refrigerant Practices Trane believes that responsible refrigerant practices are important to the environment, our customers, and The ECM variable-speed fan motors are used inReplace motor and re-check operation. Replace moduHow to Troubleshoot a Trane ECM Condenser Mo

Health Tips for Fargo craigslist personals

Nov 24, 2020 · 3-Phase Power Troubleshooting: In the event that.

14 Nov 2016 ... I soldered the new Thermistor to the ECM and now the fan will initially try to start, will begin to spin up for 2-3 seconds and then shuts down.Pielet2 • 2 yr. ago. There's two quarter inch screws on the back of the motor. Take those out and the whole back side comes off and you'll see a control board inside. More than likely you'll see a burned up or cracked resistor kind of right in the middle. Obviously do this with all the power off to the unit.I'm specifically trying to understand how the 16-pin cable works for controlling this ECM 2.3 motor. My furnace control board is a White-Rodgers Intell-Ignition, #D341420P01 My blower motor is a GE, Stock No. 5462. GE Trane 5SME39HL0252 ECM2.3, D341314P04, 1/2 HP Furnace Blower Motor.Mar 2, 2020 · A major cause of failure occurs when a blower is applied to an application with static pressure above .8” WG. This not only shortens the life of an ECM, but also a PSC. With an ECM this will cause a failure of the metal oxide varistor (MOV), a disk in the controller. If the MOV has failed, it would typically be discolored, cracked, or broken ... May 12, 2019 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ... In this HVACR Troubleshooting Video, I go over how to make your own testing connector for ECM 2.3 Variable Speed Blower Motors. I show which wires in the plu...The manufacturer or seller cannot be responsible for the interpretation of the information contained herein, nor can it assume any liability in connection with its use. Solution: The information below is from the unit Power Wiring diagram, below that is a visual on changing the motor speed on an electromechanical Precedent unit. WARNING ...In this video, you will learn 4 symptoms of a bad or failing engine control module. Watching this video will help you diagnose to see if it's time to replace...The motor will be locked out until the cause has been resolved, and the power cycled; refer to Displayed during refer to “Troubleshooting (ECM), ” p. 103 for resolution details. …Control. The ECM Fan Control controls the variable speed motor. There is a bank of 8 dip switches. The dip switches work in pairs to match the airflow for the outdoor unit size …- Apply 24vac COMMON to the 1-3 jumper. - Apply 24vac HOT to the 12-15 jumper. - Does the motor run? If so, the problem more than likely lies in the board. - If the motor does not run, you will need to investigate the motor and module. © Munch's Supply 2019. All rights reserved. 03860_1119 011164-19Remove these two bolts from the motor and control assembly while holding the motor in a way that will prevent the motor or control from falling when the bolts are removed. If an ECM2.0 control is being replaced (recognized by an aluminum casting rather than a deep-drawn black steel can housing the electronics), remove only the hex-head bolts.Trane Heat pump help needed! Good day everyone. I am new here, so hopefully i have posted this correctly. I am currently troubleshooting a Trane heat pump. model 4TWX5036A1000AA. The condenser fan with ecm motor basically "pulsates" trys to run, moves a bit , stops and repeats continuously. I have used my service manuals, and I believe its ...LOCH- ECM Troubleshooting Guide. David Harris. 12 days ago. Updated. ECM troubleshooting Macon Product.pdf. 600 KB Download. Local Trane Parts Stores Identify, Procure, and Expedite Parts for Trane Commercial Products. Service Manual/ Error Codes and Diagnostics /Wiring Diagrams. The SF Universal Indoor ECM features an auto-sizing mode which after a roughly three minute cycle "self-programs" the motor based on the static pressure in the application. The auto-sizing cycle will confi gure the correct speed and torque settings for the unit. This allows you to diagnose, install, and fi x X-13® motor replacements in one trip.Page 103: Troubleshooting (Ecm) ON. Notes: • The new Trane BLDC system is a closed loop system that has equipment protections and envelope enforcements. Do not assume that the motor has failed without first consulting the ECM engine status/ diagnostics screen. Page 104: General Information (Ecm) motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. Some models are available with high efficiency blowers. STYLINGECM Motors Troubleshooting Tips WARNING • VelociTach motor control board configuration must Hazardous Voltage! perfectly match the factory-supplied ECM. Failure to disconnect power before servicing could – Refer to “Adjustments, ” page 92 for configuration of result in death or serious injury. Disconnect all electric the motor control ...May 12, 2019 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ... These air terminal devices and heating products offer high-quality controls for efficient operation, and flexibility construction that can assure easy installation and service. We design UniTrane fan coil units as an …GE. Since the early 1990ʼs most manufacturers have used the GE ECM by Regal-Beloit motor in their variable speed products. The brand name for this motor is the Think Tank which covers models ECM 2.0, 2.3, 2.5 and 3.0. ECM 2.0 ECM 2.3/2.5 ECM 3.0 The three main benefits of this motor over conventional induction motors (PSC)The ECM motor is disassembled and all parts shown. Overview of the electronics in the end bell. Troubleshoot of end bell and motor are covered.This video i...GENTEQ®. The Genteq® brand has earned a reputation as an industry leader of ECM motors for over 30 years. These motors and blowers are used in the air moving, residential, and light commercial HVAC industries, providing unmatched performance. Genteq® motors and blowers provide high efficiency, variable speed, and low noise, …TR200 VFDs are orderable factory-mounted and commissioned on IntelliPak, Voyager III, and M-Series and T-Series Climate Changers. Trane TR200 VFDs are also integral to CenTraVac Remote Mounted Air-Cooled AFDs. The Trane TR200 features and flexibility also make it ideal for stand-alone control of exhaust fans, pumps, and cooling towers. Our ...For example, ECM motors have an electronic digital driver that is set using DIP switches or other means. An incorrect low torque setting yields low blower speed. I recommend you post the exact model number of your air handler as well as a photo of the interior showing the back end of the blower motor and the control board. A close up of …May 5, 2017 · Fan coil or furnace ECM motor repair process from diagnosing the problem to part identification and replacement along with other helpful tips.What is an ECM ... This manual contains most Trane branded SamsuVerify 24 vac is present on motor terminal 15 (wire 117V

Top Travel Destinations in 2024

Top Travel Destinations - 19 Mei 2021 ... In this HVAC training article, we will be discussin

Jan 15, 2015 · Trane variable speed blower motor, module and board problems. I was diagnosing a variable speed blower motor it was comin on for a few minutes then shut off so I replaced the motor , module and board also ohm out the 16 pin plug had continuity . And now the motor is rocking back and forth repeatedly. The ECM variable-speed fan motors are used in condensers that have a modulating compressor. They are also used in condensers that have two compressors or two-stage compressors. The ECM motor adds to the efficiency of the system by modulating the condenser fan motor. The speed matches the compressor that runs based on demand.GENTEQ. UNSPSC. 26101805. Country of Origin. Mexico (subject to change) Product Description. These programming and diagnostic tools are compatible with a specific series of motors and are primarily used with electronically commutated (EC) motors. Product Details Feedback.... Trane condenser uses an ECM variable-speed fan motor. On ... Troubleshooting Variable Speed ECM Condenser Fan Motors. ECM Motor and Control Module ...POSSIBLE CAUSE: It could be the result of a clogged cooling coil.Debris can easily stick to the inlet side of the cooling coil in your unit. Ordinary house dust as well as debris like soot and pollen can all block up indoor air handler coils as well. Trane ECM 2.3 motor module 16 pin connector signaling. Have seen posts that the 16 pin connector has signaling for delay tap, cool tap select, Adjust tap and heat tap that can be either full wave 24 VAC, 12VDC and also + or - half wave rectified by simple diode from the 24VAC transformer.Page 49 Mix Box Damper Linkage If a fire hazard exists, Trane recommends using Flexweave 1000, type FW30 or equivalent canvas. Use three inches 1. Verify bearing bracket on back damper is biased to the for the return duct and three inches for the discharge duct. Page 50 Installation Mechanical Figure 40. The ECM Motor. One of the major improvements for air conditioners and furnaces is something called an ECM motor, also referred to as a variable speed motor. The letters ECM stand for electronically commutated motor, which might sound a bit complex to understand. In the simplest terms, an ECM motor lowers the total electrical …This Trane motor is a 3/4 horsepower, 208-230 volt, 48 frame ECM motor. It is designed to provide efficient and reliable performance for a variety of HVAC ...LOCH- ECM Troubleshooting Guide. David Harris. 12 days ago. Updated. ECM troubleshooting Macon Product.pdf. 600 KB Download. Local Trane Parts Stores Identify, Procure, and Expedite Parts for Trane Commercial Products. Service Manual/ Error Codes and Diagnostics /Wiring Diagrams.Resolution: Jumper may be missing or needs to be removed from motor plug to reverse motor rotation. See attached diagram. Jumper is on lines 22-23 on your unit schematic. Jumper is between P5 and P11 on motor plug for single phase units. On three phase units with 1.5 or 3 HP motors the jumper is located on the 12 pin connector at the drive.Follow our interactive troubleshooting guide to find answers to your system’s problems. ... By Pressing submit, I consent that my information be shared with Trane approved affiliates and third party partners, including connecting me with a local Trane dealer to be contacted about products and services.GE Genteq ECM 2.3 1/2 HP Blower Motor 5SME39HL0252 D341314P02 D341314P04 MOTO9232 quantity. Add to cart. Add to cart. We ship same day if ordered by 3PM ET M-F. Free ground shipping; Estimated delivery date available during checkout by UPS. All ECM motors run on 110V-120V, 208V, 220V-240V;The motor will be locked out until the cause has been resolved, and the power cycled; refer to Displayed during refer to “Troubleshooting (ECM), ” p. 103 for resolution details. …Electric ECM 2.3 Variable Speed Modules and High Efficiency Constant Torque X13 Motors used in Trane brand equipment. The new X13 high efficiency constant torque motors will require the new Pocket Programming Module. For the first time the programmer will be available directly from ServiceFirst. Motor Programmer Ordering InstructionsNov 14, 2016 · 5 posts · Joined 2016. #5 · Nov 14, 2016. supers05, I have not taken the motor out of the squirrel cage so I am not sure exactly what is says on the side of the motor, however I got the following off of the ECM. TRANE Programmable Motor Wired For HP1, Volts 115, Amps 11.0 HZ 60, Rotation CCW, D341314P05 : MOT09233. When installed properly, systems with ECMs can improve dehumidification, reduce register noise, save energy, and provide trouble-free operation. Systems with TESPs of 1.0 and higher, which are more typical than many non-performance-based contractors are willing to admit, can eat up to eight times the power they should be using.A blower motor resistor is the electric component that controls your vehicle HVAC system’s fan speed. While pretty reliable, they won’t last forever. This particular OE one (left) retired after close to 20 years on the clock. ... That quick little bit of troubleshooting told us that the heater core was good and that the blower motor had ...*See your participating independent Trane Dealer for complete program eligibility, dates, details and restrictions. Instant rebate up to $650. All sales must be to homeowners in the United States. Void where prohibited. Valid on Qualifying Equipment only. Offer valid 09/15/2023 - 11/15/2023. ¹Subject to credit approval.How to Troubleshoot a Trane ECM Condenser Motor John Israel HVAC 40.6K subscribers Subscribe 22K views 5 years ago Welcome to Israelhvac's YouTube Channel. On this channel i bring you along...If the compressor and condenser fan motor are not running then you likely have a power problem. If it is a heat pump check for a heat pump breaker trip and reset it. If it is an air conditioner check for an air conditioner breaker trip. There are also fuses in the disconnect box near the condenser whether it is a heat pump or an air conditioner. With two unique heating stages and an AFUE